Skip to main content

ifc_occurrence/table/
part1.rs

1//! Generated occurrence rows. Do not edit by hand.
2
3use super::Occurrence;
4
5/// `IfcActuator`, 7 permitted tokens.
6pub const IFCACTUATOR: Occurrence = Occurrence {
7    type_name: "IFCACTUATOR",
8    arity: 9,
9    predefined_slot: Some(8),
10    members: &[
11        "ELECTRICACTUATOR",
12        "HANDOPERATEDACTUATOR",
13        "HYDRAULICACTUATOR",
14        "PNEUMATICACTUATOR",
15        "THERMOSTATICACTUATOR",
16        "USERDEFINED",
17        "NOTDEFINED",
18    ],
19    type_class: Some("IFCACTUATORTYPE"),
20    ifc4_type_class: Some("IFCACTUATORTYPE"),
21    ifc2x3_type_class: None,
22};
23
24/// `IfcAirTerminal`, 6 permitted tokens.
25pub const IFCAIRTERMINAL: Occurrence = Occurrence {
26    type_name: "IFCAIRTERMINAL",
27    arity: 9,
28    predefined_slot: Some(8),
29    members: &[
30        "DIFFUSER",
31        "GRILLE",
32        "LOUVRE",
33        "REGISTER",
34        "USERDEFINED",
35        "NOTDEFINED",
36    ],
37    type_class: Some("IFCAIRTERMINALTYPE"),
38    ifc4_type_class: Some("IFCAIRTERMINALTYPE"),
39    ifc2x3_type_class: None,
40};
41
42/// `IfcAirTerminalBox`, 5 permitted tokens.
43pub const IFCAIRTERMINALBOX: Occurrence = Occurrence {
44    type_name: "IFCAIRTERMINALBOX",
45    arity: 9,
46    predefined_slot: Some(8),
47    members: &[
48        "CONSTANTFLOW",
49        "VARIABLEFLOWPRESSUREDEPENDANT",
50        "VARIABLEFLOWPRESSUREINDEPENDANT",
51        "USERDEFINED",
52        "NOTDEFINED",
53    ],
54    type_class: Some("IFCAIRTERMINALBOXTYPE"),
55    ifc4_type_class: Some("IFCAIRTERMINALBOXTYPE"),
56    ifc2x3_type_class: None,
57};
58
59/// `IfcAirToAirHeatRecovery`, 11 permitted tokens.
60pub const IFCAIRTOAIRHEATRECOVERY: Occurrence = Occurrence {
61    type_name: "IFCAIRTOAIRHEATRECOVERY",
62    arity: 9,
63    predefined_slot: Some(8),
64    members: &[
65        "FIXEDPLATECOUNTERFLOWEXCHANGER",
66        "FIXEDPLATECROSSFLOWEXCHANGER",
67        "FIXEDPLATEPARALLELFLOWEXCHANGER",
68        "HEATPIPE",
69        "ROTARYWHEEL",
70        "RUNAROUNDCOILLOOP",
71        "THERMOSIPHONCOILTYPEHEATEXCHANGERS",
72        "THERMOSIPHONSEALEDTUBEHEATEXCHANGERS",
73        "TWINTOWERENTHALPYRECOVERYLOOPS",
74        "USERDEFINED",
75        "NOTDEFINED",
76    ],
77    type_class: Some("IFCAIRTOAIRHEATRECOVERYTYPE"),
78    ifc4_type_class: Some("IFCAIRTOAIRHEATRECOVERYTYPE"),
79    ifc2x3_type_class: None,
80};
81
82/// `IfcAlarm`, 10 permitted tokens.
83pub const IFCALARM: Occurrence = Occurrence {
84    type_name: "IFCALARM",
85    arity: 9,
86    predefined_slot: Some(8),
87    members: &[
88        "BELL",
89        "BREAKGLASSBUTTON",
90        "LIGHT",
91        "MANUALPULLBOX",
92        "RAILWAYCROCODILE",
93        "RAILWAYDETONATOR",
94        "SIREN",
95        "WHISTLE",
96        "USERDEFINED",
97        "NOTDEFINED",
98    ],
99    type_class: Some("IFCALARMTYPE"),
100    ifc4_type_class: Some("IFCALARMTYPE"),
101    ifc2x3_type_class: None,
102};
103
104/// `IfcAudioVisualAppliance`, 15 permitted tokens.
105pub const IFCAUDIOVISUALAPPLIANCE: Occurrence = Occurrence {
106    type_name: "IFCAUDIOVISUALAPPLIANCE",
107    arity: 9,
108    predefined_slot: Some(8),
109    members: &[
110        "AMPLIFIER",
111        "CAMERA",
112        "COMMUNICATIONTERMINAL",
113        "DISPLAY",
114        "MICROPHONE",
115        "PLAYER",
116        "PROJECTOR",
117        "RECEIVER",
118        "RECORDINGEQUIPMENT",
119        "SPEAKER",
120        "SWITCHER",
121        "TELEPHONE",
122        "TUNER",
123        "USERDEFINED",
124        "NOTDEFINED",
125    ],
126    type_class: Some("IFCAUDIOVISUALAPPLIANCETYPE"),
127    ifc4_type_class: Some("IFCAUDIOVISUALAPPLIANCETYPE"),
128    ifc2x3_type_class: None,
129};
130
131/// `IfcBeam`, 14 permitted tokens.
132pub const IFCBEAM: Occurrence = Occurrence {
133    type_name: "IFCBEAM",
134    arity: 9,
135    predefined_slot: Some(8),
136    members: &[
137        "BEAM",
138        "CORNICE",
139        "DIAPHRAGM",
140        "EDGEBEAM",
141        "GIRDER_SEGMENT",
142        "HATSTONE",
143        "HOLLOWCORE",
144        "JOIST",
145        "LINTEL",
146        "PIERCAP",
147        "SPANDREL",
148        "T_BEAM",
149        "USERDEFINED",
150        "NOTDEFINED",
151    ],
152    type_class: Some("IFCBEAMTYPE"),
153    ifc4_type_class: Some("IFCBEAMTYPE"),
154    ifc2x3_type_class: Some("IFCBEAMTYPE"),
155};
156
157/// `IfcBearing`, 10 permitted tokens.
158pub const IFCBEARING: Occurrence = Occurrence {
159    type_name: "IFCBEARING",
160    arity: 9,
161    predefined_slot: Some(8),
162    members: &[
163        "CYLINDRICAL",
164        "DISK",
165        "ELASTOMERIC",
166        "GUIDE",
167        "POT",
168        "ROCKER",
169        "ROLLER",
170        "SPHERICAL",
171        "USERDEFINED",
172        "NOTDEFINED",
173    ],
174    type_class: Some("IFCBEARINGTYPE"),
175    ifc4_type_class: None,
176    ifc2x3_type_class: None,
177};
178
179/// `IfcBoiler`, 4 permitted tokens.
180pub const IFCBOILER: Occurrence = Occurrence {
181    type_name: "IFCBOILER",
182    arity: 9,
183    predefined_slot: Some(8),
184    members: &["STEAM", "WATER", "USERDEFINED", "NOTDEFINED"],
185    type_class: Some("IFCBOILERTYPE"),
186    ifc4_type_class: Some("IFCBOILERTYPE"),
187    ifc2x3_type_class: None,
188};
189
190/// `IfcBorehole`, 0 permitted tokens.
191pub const IFCBOREHOLE: Occurrence = Occurrence {
192    type_name: "IFCBOREHOLE",
193    arity: 8,
194    predefined_slot: None,
195    members: &[],
196    type_class: None,
197    ifc4_type_class: None,
198    ifc2x3_type_class: None,
199};
200
201/// `IfcBuildingElementPart`, 7 permitted tokens.
202pub const IFCBUILDINGELEMENTPART: Occurrence = Occurrence {
203    type_name: "IFCBUILDINGELEMENTPART",
204    arity: 9,
205    predefined_slot: Some(8),
206    members: &[
207        "APRON",
208        "ARMOURUNIT",
209        "INSULATION",
210        "PRECASTPANEL",
211        "SAFETYCAGE",
212        "USERDEFINED",
213        "NOTDEFINED",
214    ],
215    type_class: Some("IFCBUILDINGELEMENTPARTTYPE"),
216    ifc4_type_class: Some("IFCBUILDINGELEMENTPARTTYPE"),
217    ifc2x3_type_class: None,
218};
219
220/// `IfcBuildingElementProxy`, 7 permitted tokens.
221pub const IFCBUILDINGELEMENTPROXY: Occurrence = Occurrence {
222    type_name: "IFCBUILDINGELEMENTPROXY",
223    arity: 9,
224    predefined_slot: Some(8),
225    members: &[
226        "COMPLEX",
227        "ELEMENT",
228        "PARTIAL",
229        "PROVISIONFORSPACE",
230        "PROVISIONFORVOID",
231        "USERDEFINED",
232        "NOTDEFINED",
233    ],
234    type_class: Some("IFCBUILDINGELEMENTPROXYTYPE"),
235    ifc4_type_class: Some("IFCBUILDINGELEMENTPROXYTYPE"),
236    ifc2x3_type_class: Some("IFCBUILDINGELEMENTPROXYTYPE"),
237};
238
239/// `IfcBuiltElement`, 0 permitted tokens.
240pub const IFCBUILTELEMENT: Occurrence = Occurrence {
241    type_name: "IFCBUILTELEMENT",
242    arity: 8,
243    predefined_slot: None,
244    members: &[],
245    type_class: None,
246    ifc4_type_class: None,
247    ifc2x3_type_class: None,
248};
249
250/// `IfcBurner`, 2 permitted tokens.
251pub const IFCBURNER: Occurrence = Occurrence {
252    type_name: "IFCBURNER",
253    arity: 9,
254    predefined_slot: Some(8),
255    members: &["USERDEFINED", "NOTDEFINED"],
256    type_class: Some("IFCBURNERTYPE"),
257    ifc4_type_class: Some("IFCBURNERTYPE"),
258    ifc2x3_type_class: None,
259};
260
261/// `IfcCableCarrierFitting`, 9 permitted tokens.
262pub const IFCCABLECARRIERFITTING: Occurrence = Occurrence {
263    type_name: "IFCCABLECARRIERFITTING",
264    arity: 9,
265    predefined_slot: Some(8),
266    members: &[
267        "BEND",
268        "CONNECTOR",
269        "CROSS",
270        "JUNCTION",
271        "REDUCER",
272        "TEE",
273        "TRANSITION",
274        "USERDEFINED",
275        "NOTDEFINED",
276    ],
277    type_class: Some("IFCCABLECARRIERFITTINGTYPE"),
278    ifc4_type_class: Some("IFCCABLECARRIERFITTINGTYPE"),
279    ifc2x3_type_class: None,
280};
281
282/// `IfcCableCarrierSegment`, 9 permitted tokens.
283pub const IFCCABLECARRIERSEGMENT: Occurrence = Occurrence {
284    type_name: "IFCCABLECARRIERSEGMENT",
285    arity: 9,
286    predefined_slot: Some(8),
287    members: &[
288        "CABLEBRACKET",
289        "CABLELADDERSEGMENT",
290        "CABLETRAYSEGMENT",
291        "CABLETRUNKINGSEGMENT",
292        "CATENARYWIRE",
293        "CONDUITSEGMENT",
294        "DROPPER",
295        "USERDEFINED",
296        "NOTDEFINED",
297    ],
298    type_class: Some("IFCCABLECARRIERSEGMENTTYPE"),
299    ifc4_type_class: Some("IFCCABLECARRIERSEGMENTTYPE"),
300    ifc2x3_type_class: None,
301};
302
303/// `IfcCableFitting`, 8 permitted tokens.
304pub const IFCCABLEFITTING: Occurrence = Occurrence {
305    type_name: "IFCCABLEFITTING",
306    arity: 9,
307    predefined_slot: Some(8),
308    members: &[
309        "CONNECTOR",
310        "ENTRY",
311        "EXIT",
312        "FANOUT",
313        "JUNCTION",
314        "TRANSITION",
315        "USERDEFINED",
316        "NOTDEFINED",
317    ],
318    type_class: Some("IFCCABLEFITTINGTYPE"),
319    ifc4_type_class: Some("IFCCABLEFITTINGTYPE"),
320    ifc2x3_type_class: None,
321};
322
323/// `IfcCableSegment`, 12 permitted tokens.
324pub const IFCCABLESEGMENT: Occurrence = Occurrence {
325    type_name: "IFCCABLESEGMENT",
326    arity: 9,
327    predefined_slot: Some(8),
328    members: &[
329        "BUSBARSEGMENT",
330        "CABLESEGMENT",
331        "CONDUCTORSEGMENT",
332        "CONTACTWIRESEGMENT",
333        "CORESEGMENT",
334        "FIBERSEGMENT",
335        "FIBERTUBE",
336        "OPTICALCABLESEGMENT",
337        "STITCHWIRE",
338        "WIREPAIRSEGMENT",
339        "USERDEFINED",
340        "NOTDEFINED",
341    ],
342    type_class: Some("IFCCABLESEGMENTTYPE"),
343    ifc4_type_class: Some("IFCCABLESEGMENTTYPE"),
344    ifc2x3_type_class: None,
345};
346
347/// `IfcCaissonFoundation`, 4 permitted tokens.
348pub const IFCCAISSONFOUNDATION: Occurrence = Occurrence {
349    type_name: "IFCCAISSONFOUNDATION",
350    arity: 9,
351    predefined_slot: Some(8),
352    members: &["CAISSON", "WELL", "USERDEFINED", "NOTDEFINED"],
353    type_class: Some("IFCCAISSONFOUNDATIONTYPE"),
354    ifc4_type_class: None,
355    ifc2x3_type_class: None,
356};
357
358/// `IfcChiller`, 5 permitted tokens.
359pub const IFCCHILLER: Occurrence = Occurrence {
360    type_name: "IFCCHILLER",
361    arity: 9,
362    predefined_slot: Some(8),
363    members: &[
364        "AIRCOOLED",
365        "HEATRECOVERY",
366        "WATERCOOLED",
367        "USERDEFINED",
368        "NOTDEFINED",
369    ],
370    type_class: Some("IFCCHILLERTYPE"),
371    ifc4_type_class: Some("IFCCHILLERTYPE"),
372    ifc2x3_type_class: None,
373};
374
375/// `IfcChimney`, 2 permitted tokens.
376pub const IFCCHIMNEY: Occurrence = Occurrence {
377    type_name: "IFCCHIMNEY",
378    arity: 9,
379    predefined_slot: Some(8),
380    members: &["USERDEFINED", "NOTDEFINED"],
381    type_class: Some("IFCCHIMNEYTYPE"),
382    ifc4_type_class: Some("IFCCHIMNEYTYPE"),
383    ifc2x3_type_class: None,
384};
385
386/// `IfcCivilElement`, 0 permitted tokens.
387pub const IFCCIVILELEMENT: Occurrence = Occurrence {
388    type_name: "IFCCIVILELEMENT",
389    arity: 8,
390    predefined_slot: None,
391    members: &[],
392    type_class: None,
393    ifc4_type_class: None,
394    ifc2x3_type_class: None,
395};
396
397/// `IfcCoil`, 9 permitted tokens.
398pub const IFCCOIL: Occurrence = Occurrence {
399    type_name: "IFCCOIL",
400    arity: 9,
401    predefined_slot: Some(8),
402    members: &[
403        "DXCOOLINGCOIL",
404        "ELECTRICHEATINGCOIL",
405        "GASHEATINGCOIL",
406        "HYDRONICCOIL",
407        "STEAMHEATINGCOIL",
408        "WATERCOOLINGCOIL",
409        "WATERHEATINGCOIL",
410        "USERDEFINED",
411        "NOTDEFINED",
412    ],
413    type_class: Some("IFCCOILTYPE"),
414    ifc4_type_class: Some("IFCCOILTYPE"),
415    ifc2x3_type_class: None,
416};
417
418/// `IfcColumn`, 7 permitted tokens.
419pub const IFCCOLUMN: Occurrence = Occurrence {
420    type_name: "IFCCOLUMN",
421    arity: 9,
422    predefined_slot: Some(8),
423    members: &[
424        "COLUMN",
425        "PIERSTEM",
426        "PIERSTEM_SEGMENT",
427        "PILASTER",
428        "STANDCOLUMN",
429        "USERDEFINED",
430        "NOTDEFINED",
431    ],
432    type_class: Some("IFCCOLUMNTYPE"),
433    ifc4_type_class: Some("IFCCOLUMNTYPE"),
434    ifc2x3_type_class: Some("IFCCOLUMNTYPE"),
435};
436
437/// `IfcCommunicationsAppliance`, 26 permitted tokens.
438pub const IFCCOMMUNICATIONSAPPLIANCE: Occurrence = Occurrence {
439    type_name: "IFCCOMMUNICATIONSAPPLIANCE",
440    arity: 9,
441    predefined_slot: Some(8),
442    members: &[
443        "ANTENNA",
444        "AUTOMATON",
445        "COMPUTER",
446        "FAX",
447        "GATEWAY",
448        "INTELLIGENTPERIPHERAL",
449        "IPNETWORKEQUIPMENT",
450        "LINESIDEELECTRONICUNIT",
451        "MODEM",
452        "NETWORKAPPLIANCE",
453        "NETWORKBRIDGE",
454        "NETWORKHUB",
455        "OPTICALLINETERMINAL",
456        "OPTICALNETWORKUNIT",
457        "PRINTER",
458        "RADIOBLOCKCENTER",
459        "REPEATER",
460        "ROUTER",
461        "SCANNER",
462        "TELECOMMAND",
463        "TELEPHONYEXCHANGE",
464        "TRANSITIONCOMPONENT",
465        "TRANSPONDER",
466        "TRANSPORTEQUIPMENT",
467        "USERDEFINED",
468        "NOTDEFINED",
469    ],
470    type_class: Some("IFCCOMMUNICATIONSAPPLIANCETYPE"),
471    ifc4_type_class: Some("IFCCOMMUNICATIONSAPPLIANCETYPE"),
472    ifc2x3_type_class: None,
473};
474
475/// `IfcCompressor`, 17 permitted tokens.
476pub const IFCCOMPRESSOR: Occurrence = Occurrence {
477    type_name: "IFCCOMPRESSOR",
478    arity: 9,
479    predefined_slot: Some(8),
480    members: &[
481        "BOOSTER",
482        "DYNAMIC",
483        "HERMETIC",
484        "OPENTYPE",
485        "RECIPROCATING",
486        "ROLLINGPISTON",
487        "ROTARY",
488        "ROTARYVANE",
489        "SCROLL",
490        "SEMIHERMETIC",
491        "SINGLESCREW",
492        "SINGLESTAGE",
493        "TROCHOIDAL",
494        "TWINSCREW",
495        "WELDEDSHELLHERMETIC",
496        "USERDEFINED",
497        "NOTDEFINED",
498    ],
499    type_class: Some("IFCCOMPRESSORTYPE"),
500    ifc4_type_class: Some("IFCCOMPRESSORTYPE"),
501    ifc2x3_type_class: None,
502};
503
504/// `IfcCondenser`, 9 permitted tokens.
505pub const IFCCONDENSER: Occurrence = Occurrence {
506    type_name: "IFCCONDENSER",
507    arity: 9,
508    predefined_slot: Some(8),
509    members: &[
510        "AIRCOOLED",
511        "EVAPORATIVECOOLED",
512        "WATERCOOLED",
513        "WATERCOOLEDBRAZEDPLATE",
514        "WATERCOOLEDSHELLCOIL",
515        "WATERCOOLEDSHELLTUBE",
516        "WATERCOOLEDTUBEINTUBE",
517        "USERDEFINED",
518        "NOTDEFINED",
519    ],
520    type_class: Some("IFCCONDENSERTYPE"),
521    ifc4_type_class: Some("IFCCONDENSERTYPE"),
522    ifc2x3_type_class: None,
523};
524
525/// `IfcController`, 7 permitted tokens.
526pub const IFCCONTROLLER: Occurrence = Occurrence {
527    type_name: "IFCCONTROLLER",
528    arity: 9,
529    predefined_slot: Some(8),
530    members: &[
531        "FLOATING",
532        "MULTIPOSITION",
533        "PROGRAMMABLE",
534        "PROPORTIONAL",
535        "TWOPOSITION",
536        "USERDEFINED",
537        "NOTDEFINED",
538    ],
539    type_class: Some("IFCCONTROLLERTYPE"),
540    ifc4_type_class: Some("IFCCONTROLLERTYPE"),
541    ifc2x3_type_class: None,
542};
543
544/// `IfcConveyorSegment`, 6 permitted tokens.
545pub const IFCCONVEYORSEGMENT: Occurrence = Occurrence {
546    type_name: "IFCCONVEYORSEGMENT",
547    arity: 9,
548    predefined_slot: Some(8),
549    members: &[
550        "BELTCONVEYOR",
551        "BUCKETCONVEYOR",
552        "CHUTECONVEYOR",
553        "SCREWCONVEYOR",
554        "USERDEFINED",
555        "NOTDEFINED",
556    ],
557    type_class: Some("IFCCONVEYORSEGMENTTYPE"),
558    ifc4_type_class: None,
559    ifc2x3_type_class: None,
560};